Abstract:A simple design method for capacitor-current feedback coefficients with clear physical significance is proposed to address the complexity of feedback coefficient design in LCL-type grid-connected inverters when capacitor-current feedback active damping is adopted for resonance suppression. First, the intrinsic relationship between two passive damping schemes—namely, series and parallel resistors in the capacitor branch—is analyzed from the perspective of damping ratio. Second, through equivalent transformation of the control block diagram, the equivalence between capacitor-current feedback active damping and the aforementioned passive damping schemes is examined, and consequently, the relationship between the capacitor-current feedback coefficient and the passive damping resistor is established. Third, the dependence of the capacitor-current feedback coefficient on the LCL filter parameters and the PWM modulation gain is derived, and the feedback coefficient is determined according to the commonly used passive damping resistor selection principle in engineering practice. Finally, the proposed method is validated through Matlab/Simulink simulations.